MTT Tank Farm and Facilities

          The 33 tanks whose capacities to store various liquid chemical vary from 1,000 up to 70,000 ton are well-equipped with reliable systems for detecting leaks, recording dead stock, monitoring tank status, and making transfers among tanks. Additional capacities can be created to suit specific requirements of the customer at attractive commercial terms.

Jetty Specification

          Our jetty could support up to 100,000 DWT of vessel, together with monitoring and controlling movement throughout its entire journey, from storage at tank farms to distribution at marketing terminals into marine vessels and also truck loading. Moreover the jetty performance is now controlled by key performance indicators under international standard, ISO 9001. Since the jetties are equipped with various types of loading arms, they should therefore be used in accordance with their operating limits seen below.

Jetty Parameters & Loading Arm Size

Jetty No.1 :

Product
DWT
Allowable draft at all times
LOA
Max. Beam
Parallel Body Length
Distance from bow to center manifold
Distance from stern to center manifold
Distance from rail to manifold
Distance from deck to center manifold
Loading arm size
Naphtha
1,000-100,000
14.0 m.
85-260 m.
46 m.
>48.5 m.
27.25-132.25 m.
22.75-127.75 m.
>1.5 m.
>0.5 m.
2x16 inch ANSI 150
Light Reformate / Raw Pygas
1,000-100,000
14.0 m.
85-260 m.
46 m.
>39.5 m.

22.75-127.75 m.
27.25-132.25 m.
>0.95 m.
>0.45 m.
1x8 inch ANSI 150
Benzene
1,000-100,000
14.0 m.
85-260 m.
46 m.
>39.5 m.

22.75-127.75 m.
27.25-132.25 m.
>0.95 m.
>0.45 m.
1x8 inch ANSI 150
1x4 inch ANSI 150 (vapor)
Toluene
1,000-100,000
14.0 m.
85-260 m.
46 m.
>39.5 m.

22.75-127.75 m.
27.25-132.25 m.
>0.95 m.
>0.45 m.
1x8 inch ANSI 150
1x4 inch ANSI 150 (vapor)
Mixed Xylene
1,000-100,000
14.0 m.
85-260 m.
46 m.
>39.5 m.

22.75-127.75 m.
27.25-132.25 m.
>0.95 m.
>0.45 m.
1x8 inch ANSI 150
1x4 inch ANSI 150 (vapor)
Paraxylene
1,000-100,000
14.0 m.
85-260 m.
46 m.
>39.5 m.

22.75-127.75 m.
27.25-132.25 m.
>0.95 m.
>0.45 m.
1x8 inch ANSI 150
MMA
1,000-100,000
14.0 m.
85-260 m.
46 m.
>29.5 m.

38.25-143.25 m.
11.75-116.75 m.
>1.0 m.
>0.4 m.
1x6 inch ANSI 150
Propane
1,000-100,000
14.0 m.
85-260 m.
46 m.
>33.5 m.

18.75-123.75 m.
31.25-136.25 m.
>1.5 m.
>0.5 m.
1x12 inch ANSI 150
Butane
1,000-100,000
14.0 m.
85-260 m.
46 m.
>33.5 m.

18.75-123.75 m.
31.25-136.25 m.
>1.5 m.
>0.5 m.
1x12 inch ANSI 150

Jetty No.2 :

Product
DWT
Allowable draft at all times
LOA
Max. Beam
Parallel Body Length
Distance from bow to center manifold
Distance from stern to center manifold
Distance from rail to manifold
Distance from deck to center manifold
Loading arm size
Ethylene
1,000-20,000
9.5 m.
60-170 m.
30 m.
>31.5 m.
39.25-92.25 m.
13.75-77.75 m.
>1.06 m.
>0.35 m.
1x8 inch ANSI 300
Propylene
1,000-20,000
9.5 m.
60-170 m.
30 m.
>31.5 m.
39.25-92.25 m.
13.75-77.75 m.
>1.06 m.
>0.35 m.
1x8 inch ANSI 300
1x4 inch ANSI 150 (vapor)
Butadiene
1,000-20,000
9.5 m.
60-170 m.
30 m.
>23.5 m.
32.00-96.25 m.
9.75-73.75 m.
>0.868 m.
>0.35 m.
1x6 inch ANSI 300
1x4 inch ANSI 150 (vapor)
Butene-1
1,000-20,000
9.5 m.
60-170 m.
30 m.
>23.5 m.
32.00-96.25 m.
9.75-73.75 m.
>0.868 m.
>0.35 m.
1x6 inch ANSI 300
1x4 inch ANSI 150 (vapor)
Mixed C4
1,000-20,000
9.5 m.
60-170 m.
30 m.
>23.5 m.
32.00-96.25 m.
9.75-73.75 m.
>0.868 m.
>0.35 m.
1x6 inch ANSI 300
1x4 inch ANSI 150 (vapor)
MMA
1,000-20,000
9.5 m.
60-170 m.
30 m.
>23.5 m.
25.25-78.25 m.
27.75-91.75 m.
>0.87 m.
>0.3 m.
1x6 inch ANSI 150
TBA
1,000-20,000
9.5 m.
60-170 m.
30 m.
>23.5 m.
28.75-81.75 m.
24.25-88.25 m.
>0.87 m.
>0.3 m.
1x6 inch ANSI 150
Methanol
1,000-20,000
9.5 m.
60-170 m.
30 m.
>23.5 m.
28.75-81.75 m.
24.25-88.25 m.
>0.87 m.
>0.3 m.
1x6 inch ANSI 150
MEG
1,000-20,000
9.5 m.
60-170 m.
30 m.
>30.5 m.
21.75-74.75 m.
31.25-95.25 m.
>0.85 m.
>0.4 m.
1x6 inch ANSI 150
AA
1,000-20,000
9.5 m.
60-170 m.
30 m.
>37.5 m.
18.25-71.25 m.
34.75-98.75 m.
>0.87 m.
>0.3 m.
1x6 inch ANSI 150

Jetty No.3 :

Product
DWT
Allowable draft at all times
LOA
Max. Beam
Parallel Body Length
Distance from bow to center manifold
Distance from stern to center manifold
Distance from rail to manifold
Distance from deck to center manifold
Loading arm size
Naphtha
1,000-80,000
10.1 m.
85-220 m.
40 m.
>44 m.
21.0-115.68 m.
16.0-104.32 m.
>1.5 m.
>0.5 m.
2x16 inch ANSI 150
Benzene
1,000-80,000
10.1 m.
85-220 m.
40 m.
>23 m.
5.5-100.18 m.
31.5-119.82 m.
>0.95 m.
>0.45 m.
1x8 inch ANSI 300
1x4 inch ANSI 150 (vapor)
C9+ / C8+
1,000-80,000
10.1 m.
85-220 m.
40 m.
>23 m.
5.5-100.18 m.
31.5-119.82 m.
>0.95 m.
>0.45 m.
1x8 inch ANSI 300
1x4 inch ANSI 150 (vapor)
Paraxylene
1,000-80,000
10.1 m.
85-220 m.
40 m.
>23 m.
5.5-100.18 m.
31.5-119.82 m.
>0.95 m.
>0.45 m.
1x8 inch ANSI 300
Methanol
1,000-80,000
10.1 m.
85-220 m.
40 m.
>23 m.
5.5-100.18 m.
31.5-119.82 m.
>0.95 m.
>0.45 m.
1x6 inch ANSI 150
Octene
1,000-80,000
10.1 m.
85-220 m.
40 m.
>30 m.
9.5-104.18 m.
27.5-115.82 m.
>0.95 m.
>0.4 m.
1x8 inch ANSI 300
1x4 inch ANSI 150 (vapor)
Hexene
1,000-80,000
10.1 m.
85-220 m.
40 m.
>30 m.
9.5-104.18 m.
27.5-115.82 m.
>0.95 m.
>0.4 m.
1x8 inch ANSI 300
1x4 inch ANSI 150 (vapor)
Solvent
1,000-80,000
10.1 m.
85-220 m.
40 m.
>37 m.
13.5-108.18 m.
23.5-111.82 m.
>0.95 m.
>0.4 m.
1x8 inch ANSI 300
1x4 inch ANSI 150 (vapor)

Jetty No.4 :

Product
DWT
Allowable draft at all times
LOA
Max. Beam
Parallel Body Length
Distance from bow to center manifold
Distance from stern to center manifold
Distance from rail to manifold
Distance from deck to center manifold
Loading arm size
Toluene
1,000-10,000
7.7 m.
60-115 m.
25 m.
>23 m.
11.5-69.08 m.
24.5-57.92 m.
>0.709 m.
>0.35 m.
1x8 inch ANSI 300
1x4 inch ANSI 150 (vapor)
Mixed Xylene
1,000-10,000
7.7 m.
60-115 m.
25 m.
>23 m.
11.5-69.08 m.
24.5-57.92 m.
>0.709 m.
>0.35 m.
1x8 inch ANSI 300
1x4 inch ANSI 150 (vapor)
Mixed C4
1,000-10,000
7.7 m.
60-115 m.
25 m.
>30 m.
15.0-72.58 m.
21.0-54.42 m.
>0.868 m.
>0.7 m.
1x8 inch ANSI 300
1x4 inch ANSI 150 (vapor)
Butene-1
1,000-10,000
7.7 m.
60-115 m.
25 m.
>30 m.
15.0-72.58 m.
21.0-54.42 m.
>0.868 m.
>0.7 m.
1x8 inch ANSI 300
1x4 inch ANSI 150 (vapor)








E-mail to us : mttplan@scg.co.th
Head office: Map Ta Phut Tank Terminal Co., Ltd., 1 Siam Cement Road, Bangsue,
Bangkok 10800, Thailand. Tel: (662) 586-5560, FAX: (662)586-5436
Terminal address: Map Ta Phut Tank Terminal Co. Ltd., 18 I-8 Road,
Map Ta Phut, Muang District, Rayong 21150, Thailand. Tel: (6638) 684447-8